SKU: 94348
Shop with confidence! This product has been fully inspected to avoid any buyer surprises. Read our in-depth product listing below.
Your purchase will NOT include: This product is pre-owned and may not include the same accessories as a new, unused unit. - other accessories not shown or listed here.This autoclave was disassembled down to it's bare chassis, cleaned and rebuilt. The Reservoir Tank was cleaned and flushed and a new Reservoir Cap, Reservoir Filter and Water Pump Filter and Drain Kit upgrade were installed. Installed a new Water Pump, Air Valve Solenoid Assembly , Check Valve, Safety Valve and Biological Filter. Cleaned the sterilizing cassette and installed a new cassette seal. Then the testing and calibration of this autoclave was started, by levelling the sterilizer for proper cassette drying, connecting it to a 120 volt power source, attaching a donor condenser waste bottle, and adding distilled water. Calibration was successful. Then this sterilizer was tested, by running it through all it's preset sterilizing and drying cycles several times. To verify that this autoclave is achieving it's maximum required sterilization temperature during a cycle, it was temperature tested using a Max Register Thermometer, and was found to exceed the required 273 F for an during a sterilization cycle
Technician Testing Notes
This autoclave was disassembled down to it's bare chassis, cleaned and rebuilt. The Reservoir Tank was cleaned and flushed and a new Reservoir Cap, Reservoir Filter and Water Pump Filter and Drain Kit upgrade were installed. Installed a new Water Pump, Air Valve Solenoid Assembly , Check Valve, Safety Valve and Biological Filter. Cleaned the sterilizing cassette and installed a new cassette seal. Then the testing and calibration of this autoclave was started, by levelling the sterilizer for proper cassette drying, connecting it to a 120 volt power source, attaching a donor condenser waste bottle, and adding distilled water. Calibration was successful. Then this sterilizer was tested, by running it through all it's preset sterilizing and drying cycles several times. To verify that this autoclave is achieving it's maximum required sterilization temperature during a cycle, it was temperature tested using a Max Register Thermometer, and was found to exceed the required 273 F for an during a sterilization cycle
This autoclave was disassembled down to it's bare chassis, cleaned and rebuilt. The Reservoir Tank was cleaned and flushed and a new Reservoir Cap, Reservoir Filter and Water Pump Filter and Drain Kit upgrade were installed. Installed a new Water Pump, Air Valve Solenoid Assembly , Check Valve, Safety Valve and Biological Filter. Cleaned the sterilizing cassette and installed a new cassette seal. Then the testing and calibration of this autoclave was started, by levelling the sterilizer for proper cassette drying, connecting it to a 120 volt power source, attaching a donor condenser waste bottle, and adding distilled water. Calibration was successful. Then this sterilizer was tested, by running it through all it's preset sterilizing and drying cycles several times. To verify that this autoclave is achieving it's maximum required sterilization temperature during a cycle, it was temperature tested using a Max Register Thermometer, and was found to exceed the required 273 F for an during a sterilization cycle
Product Condition
- Manufacturer: SciCan
- Model: STATIM 5000
- Serial Number: 5103BB0073
- Power Requirements: 110V
- Year: 2006
- Sterilizer Type: steam cassette
- Timer Function: features a timer with a variety of cycle options
- Controls: digital control display
- Chamber Depth: N/A
- Chamber Diameter: N/A
- Number of Trays: 1 tray
- Cycle Count: 2,500
Item Includes:
1 - SciCan STATIM 5000 Cassette Autoclave 1 - Sterilizing Cassette w/ Rack 1 - Condenser Waste Bottle 1 - Power Cord
Item Excludes:
This product is pre-owned and may not include the same accessories as a new, unused unit.
1 - SciCan STATIM 5000 Cassette Autoclave 1 - Sterilizing Cassette w/ Rack 1 - Condenser Waste Bottle 1 - Power Cord
Item Excludes:
This product is pre-owned and may not include the same accessories as a new, unused unit.
Shipping calculated at checkout.
30 Day Return Guarantee
Your satisfaction is important to us: Have your equipment installed by a factory-trained technician or Atlas-approved vendor to qualify for our return policy.See our Terms and Conditions of Sale for details.