Used Dental Intraoral X-Ray | Belmont Belray 096

The Belmont Belray profile and line-of-sight accurate alignment results in reproducible, high contrast, crisp radiographs with excellent image quality. The Belray is compatible with most digital imaging radiographic systems and the exposure time can be set as low as 0.02 sec.

The Belray features a microprocessor that selects the optimal exposure time based on patient and film type, cone length, and tooth to be radiographed. It has an 0.8mm focal spot and exposure times ranging from .02 to 3.0 seconds.

Features: 
  • BelSensor digital imaging sensor
  • Long cone (12”) for paralleling film technique
  • Remote exposure switch with indicator light
  • 12” or 20” horizontal arms for operatories with space constraints.
  • Pass-thru mounting plate for sharing X-ray between adjacent operatories
  • Separate microprocessor control box with patient type, tooth type, cone type, film speed and exposure time selection switches
  • Exposure can be set as low as 0.02 second, the equivalent of 1.2 impulses
Benefits: 
  • Reproducible and high quality periapical radiographs
  • Utilizes simple, intuitive controls for exposure parameter settings
  • Compatible with most digital imaging radiographic systems
  • Control is mounted separately from the arm/head for in-room or remote mounting and to simplify pass-thru installations.
Limitations/Considerations: 
  • To protect x-ray tube-head from heat accumulation, wait for 60 times of exposure time between exposures.
  • Before cleaning the unit, turn off the main power switch and breaker on the blanch line.
  • Never use the metal corrosive disinfectant, such as povidone iodine or sodium hypochlorite.
  • Do not pour or spray solvent or liquid directly on the x-ray unit.
  • Be careful not to allow solvents to run or drip into the x-ray unit. Exposure can be set as low as 0.02 second, the equivalent of 1.2 impulses
Technical Specifications: 
  • Nominal focal spot value: 0.8 mm (IEC60336)
  • Rated peak tube potential: 70 kV(peek)
  • Rated tube current: 10 mA
  • Rated Line Voltage: 230 V
  • Min Line Voltage: 207 V
  • Max Line Voltage: 253 V
  • Rated Line Power: 1.3 kVA
  • Rated Line Current: 5.6 A
  • Max Line Current: 6.2 A
  • Power line frequency: 50/60 Hz
  • Exposure time: 0.02 ~ 3 second
  • Timer accuracy: ±1 pulse (1/50sec. for 50Hz,1/60sec. for 60Hz)
  • Inherent filtration: 1.3 mmAl Equivalent
  • Regular cone: 204 mm
  • Leakage technique factor: 70 kVp / 0.16 mA
  • Duty cycle: 1: 60 (0.5 second exposure with 30 second interval)
  • Field size: Round 58 mm
  • Tolerance of the focal spot marking: ±1 mm
  • Tolerance of target angle: 1˚
  • Maximum earth leakage current: 0.5 mA
  • Focal Point: 0.8 mm
  • Maximum Rated Peak Tube Potential: 70 kVp
  • Rated Line Voltage: 120V